Skip to main content

Passive House apartment building in Rennes, Bretagne

Case study
France

Passive House apartment building in Rennes, Bretagne

25 March 2022
Editorial Team

Development from Ascension Paysagère (Rennes), block 3 ZAC de l'Octroi in Rennes: 34 dwellings
Passivhaus on 8 levels (7 floors)

 

THERMAL ENVELOPE

Exterior wall: Gypsum board 0,250 13
Concrete 2,100 200
Rockwool 0,035 200
U-value = 0.186 W/(m2K)

 

Basement floor / floor slab: Screed 1,500 50
Polyuréthane 0,022 100
Concrete 2,100 180
Terradall polystyrène 0,038 100
U-value = 0.134 W/(m2K)

 

Roof: Gypsum board 0,250 13
Concrete 2,100 200
Polyuréthane 0,022 160
U-value = 0.132 W/(m2K)

 

MECHANICAL SYSTEM

Ventilation: ALDES, VEX 580 C4
Non-certified comfort ventilation ("double flow") with cross flow from ALDES. Heat recovery efficiency = 80 % Electrical power = 0.37 Wh/m3

Heating installation: Gas condensing boiler

Domestic hot water: Gas condensing boiler

 

PHPP VALUES

Climate: Cool, temperate

Air tightness: n50 = 0.48/hSystème canalisations Lindab

Annual heating demand: 10 kWh /(m2a ) calculated according to PHPP

Heating load: 11 W/m2

PE demand (non-renewable Primary Energy): 82 kWh /(m2a ) on heating installation, domestic hot water, household electricity and auxiliary electricity calculated according to PHPP

PER demand (renewable Primary Energy): 108 kWh /(m2a ) on heating installation, domestic hot water, household electricity and auxiliary electricity calculated according to PHPP

 

Find more details here.